![]() Peaco Support phase converters features high quality with CE certified, affordable price so that customers can spend less money to afford a high performance phase converter to meet their needs of single phase to three phase in industrial field. Input voltage can be 110V/ 220V/ 240V/ 380V/ 415V AC, output voltage is optional 220V/ 380V/ 400V/ 415V/ 440V/ 480V AC and other voltage, frequency and phase of the static phase converter can be customized according to customer's special needs. The rated output power ranges from 4 hp (3 kW) to 135 hp (100 kW), 50Hz or 60Hz output frequency, converting from single phase to three phase. Peaco Support provides a wide range of phase converters, such as 240V to 415V 3 phase converter, 220V single phase to 380V 3 phase converter, 220V to 440V converter, single phase 230V to 3 phase 400V converter, 110V to 220V 3 phase converter, 240V single phase to 480V three phase converter, etc. So that a utility usually charge higher fees for three-phase services because of the need for additional equipment, including transformers, metering and distribution wires. The phase converter is used in such places where the three-phase service cannot be provided or the installation cost is too high due to the remote location. Most phase converters are used to generate three-phase power from a single-phase power source, thus allowing three-phase equipment to operate on sites where only single-phase power is served. They are the only ones who can give you the correct info you need to convert it.A phase converter is a device that converts single-phase power into multi-phase or multi-phase power into single-phase. If you want to fire it on single phase, but it's currently wired for 3 phase, call the manufacturer. Have 80 A breaker in panel available (have a big welder) Howe about running 3 middle elements in series and just leave the 4th disconnected.Ĩ.7 x 3 =26 ohms again with 150 sq inches 240x240/26=2215watts divided by 150 sq in =14 watts /sqin.ĭoes this look even close? Can I fire these elements in their groove at this level? they are really not in free air!Ī little more info - 6 mercury relays are rated 35A 600V each The middle 4 elements are another story, again 16 gauge but 8.7 ohms run in series 49 sqin x2=100 sqin watts give me 33 watts/sqinch a bit too high I think. 156=144 sqin calcs show that at 240V I would be drawing 15 Watts /sqinch which I think is a safe loading. 208V 3 ph has 8 elements, top 2 and bottom 2 measure 26 ohms/16 gauge-assuming Kanthal A1. I'm in the same boat, Paragon Viking 273 from local college. Your only other idea is what has been suggested above contact the manufacture sand ask them the details-I think you will find this is a poor fit. I suggest passing the whole deal up as its not a fit that will work no matter how good it sounds Since we (I also do not have it close-over 1 mile) its not in the cards They demand lower operating costs and pay for the power grid lines to bring in 3 phase. Thats the beauty of 3 phase for industrial equipment. Once its converted to single phase it will draw a lot more amps as any single phase does. One last note since its a fiber kiln rewiring it to single phase working with the stiff fired fiber will damage it. The only thing that made any sense was converting the shell to gas. I think since you do not have 3 phase and as you have found out it will cost more than its worth I would not even consider this. I have had somme experience with phase converters on fixed machinery but not kilns-as they are a constant draw. !st your 40 amp line is to small even for a 37 amp draw-you need more room for safety. Three phase conversions can cost a pretty penny-you will need a converter which in itself uses more power.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |